Fig. 16From: RF deflecting cavity for fast radioactive ion beamsDeformation (left) and VonMises stress (right) results of simulations on the cavity engineering model demonstrating < 0.5 mm wall deformation and no major yield issues as simulated in SolidWorksBack to article page