Skip to main content

Table 2 Comparison of activities and reaction rates of 99Mo in various Mo metal samples after one production day of 18F in a low-energy cyclotron with neutrons generated through the 18O(p, n)18F reaction

From: Hybridised production of technetium-99m and technetium-101 with fluorine-18 on a low-energy biomedical cyclotron

 

Cube 1

Cube 2

Foil 1

Mass

10.29075

10.2612

2.94533

Irradiation Time (s)

15540

16500

16500

Time after EOB (s)

98753

37736

39210

Count Time (s)

600

600

600

Total Counts 99Mo

391785

333068

197469

Total 18F Produced (Ci)

19.189

19.649

19.649

99Mo Activity (Bq)

1.28E+05

9.00E+04

5.16E+04

99Mo Activity (Ci)

3.45E–06

2.43E–06

1.40E–06

99Mo Specific Activity (Ci/g)

3.35E–07

2.37E–07

4.74E–07

Spec. Act. 99Mo (Ci/g)/18F (Ci)

1.75E–08

1.21E–08

2.41E–08

Ratio 99Mo (Ci)/18F (Ci)

1.80E–07

1.24E–07

7.10E–08

Reaction Rate of 99Mo (Bq)

2.87E+06

1.91E+06

1.10E+06

Reaction Rate of 99Mo (Ci)

7.77E–05

5.17E–05

3.93E–05

Reaction Rate of 99Mo (Ci/g)

7.55E–06

5.04E–06

1.34E–05