Table 2 rms misalignment values used in simulations presented in this paper. The definition of the misalignment parameters are defined in Fig. 2. Note that values are not tolerance specifications, as there is an ongoing iterative process to determine the alignment level achievable and the acceptable machine performance

From: Alignment & stability challenges for FCC-ee

Type

ΔX (μm)

ΔY (μm)

ΔPSI (μrad)

ΔS (μm)

ΔTHETA (μrad)

ΔPHI(μrad)

Arc quadrupoles

50

50

300

150

70

70

Arc sextupoles

50

50

300

150

70

70

Dipoles

1000

1000

300

1000

0

0

Girders

150

150

1000

  

IR quadrupole

100

100

250

250

70

70

IR sextupoles

100

100

250

250

70

70

  1. misalignments relative to girder placement